Series F22
The flanged valve of the 22 series in the control type direct and externally controlled requires compressed air between 4-8bar for switching.
The spring-loaded piston actuator is pressurised with compressed air and directly lifts the valve disc from the seat. The valve is closed by spring force.
The robust design has fast reaction times with high positioning forces of spring and control pressure.
Technical informations
Connections
DN20, DN25, DN32, DN40, DN50, DN65, DN80, DN100, DN150, DN200, DN250
Pressure
0 bar up to 16 bar
Temperature
-10 °C up to 200 °C
Type of Control
pneum. direct
Housing materials
EN-GJL250 grey cast | EN-JS1025 ductile iron
Sealing
FKM | PTFE | NBR/NBR
Media
Water, H2O, Fuel Oil, Air, Acetylene C2H2, Propane/Butane gaseous C3H8, Water H2O with Glycole, natural Gas CH4, Nitrogen Gas N2, Gasoline, Dieseloil, Fuels, Steam 180°C, Water, Hot above 90°C H2O, Steam 110°C, Condensate, Thermal-Oil >180°C, Hot Air 180°C, Bilge Water (water-oil mix), Vacuum, Vacuum + Pressure, Ethylacetat CH3 CO2 CH2 CH3, Biogas <= 0,5% H2S
All Products

F2202/0304/7005-EN
DN20
EN-JS1025 ductile iron
PTFE
0 - 16 bar
NC — closed by spring power with the flow direction
Sensor inductive, 2-fold

F2202/0304/7005-EO
DN20
EN-JS1025 ductile iron
PTFE
0 - 16 bar
NC — closed by spring power with the flow direction
Inductive sensor, double

F2202/0304/7005-OF
DN20
EN-JS1025 ductile iron
PTFE
0 - 16 bar
NC — closed by spring power with the flow direction
Free of oil and grease

F2202/0304/7005-XX
DN20
EN-JS1025 ductile iron
PTFE
0 - 16 bar
NC — closed by spring power with the flow direction
No extra options

F2202/0304/7015-EN
DN20
EN-JS1025 ductile iron
PTFE
0 - 13 bar
NC — closed by spring power against the media (soft closing)
Sensor inductive, 2-fold

F2202/0304/7015-EO
DN20
EN-JS1025 ductile iron
PTFE
0 - 13 bar
NC — closed by spring power against the media (soft closing)
Inductive sensor, double

F2202/0304/7015-EO-BIM-UNT-AG41X
DN20
EN-JS1025 ductile iron
PTFE
0 - 13 bar
NC — closed by spring power against the media (soft closing)
Magnetic switch 2-fold OPEN and CLOSE induct. 2-wire N/O contact

F2202/0304/7015-OF
DN20
EN-JS1025 ductile iron
PTFE
0 - 13 bar
NC — closed by spring power against the media (soft closing)
Free of oil and grease

F2202/0304/7015-XX
DN20
EN-JS1025 ductile iron
PTFE
0 - 13 bar
NC — closed by spring power against the media (soft closing)
No extra options

F2202/0304/7058-EN
DN20
EN-JS1025 ductile iron
PTFE
0 - 13 bar
NC — closed by spring power against the media (soft closing)
Sensor inductive, 2-fold

F2202/0304/7058-EO
DN20
EN-JS1025 ductile iron
PTFE
0 - 13 bar
NC — closed by spring power against the media (soft closing)
Inductive sensor, double

F2202/0304/7058-OF
DN20
EN-JS1025 ductile iron
PTFE
0 - 13 bar
NC — closed by spring power against the media (soft closing)
Free of oil and grease

F2202/0304/7058-XX
DN20
EN-JS1025 ductile iron
PTFE
0 - 13 bar
NC — closed by spring power against the media (soft closing)
No extra options

F2202/0304/8005-EO-BIM-UNT-AG41X
DN20
EN-JS1025 ductile iron
PTFE
0 - 16 bar
NO — open by spring power
Magnetic switch 2-fold OPEN and CLOSE induct. 2-wire N/O contact

F2202/0304/8005-XX
DN20
EN-JS1025 ductile iron
PTFE
0 - 16 bar
NO — open by spring power
No extra options

F2202/0402/7005-EB-VU
DN20
EN-GJL250 grey cast
FKM
0 - 16 bar
NC — closed by spring power with the flow direction
Reed contact 2-wire RC12 Vacuum

F2202/0402/7005-EN
DN20
EN-GJL250 grey cast
FKM
0 - 16 bar
NC — closed by spring power with the flow direction
Sensor inductive, 2-fold

F2202/0402/7005-EO
DN20
EN-GJL250 grey cast
FKM
0 - 16 bar
NC — closed by spring power with the flow direction
Inductive sensor, double

F2202/0402/7005-OF
DN20
EN-GJL250 grey cast
FKM
0 - 16 bar
NC — closed by spring power with the flow direction
Free of oil and grease

F2202/0402/7005-VD
DN20
EN-GJL250 grey cast
FKM
0 - 16 bar
NC — closed by spring power with the flow direction
vacuum + overpressure

F2202/0402/7005-XX
DN20
EN-GJL250 grey cast
FKM
0 - 16 bar
NC — closed by spring power with the flow direction
No extra options

F2202/0402/7015-EB-VU
DN20
EN-GJL250 grey cast
FKM
0 - 13 bar
NC — closed by spring power against the media (soft closing)
Reed contact 2-wire RC12 Vacuum

F2202/0402/7015-EN
DN20
EN-GJL250 grey cast
FKM
0 - 13 bar
NC — closed by spring power against the media (soft closing)
Sensor inductive, 2-fold

F2202/0402/7015-EO
DN20
EN-GJL250 grey cast
FKM
0 - 13 bar
NC — closed by spring power against the media (soft closing)
Inductive sensor, double

F2202/0402/7015-EO-BIM-UNT-AG41X
DN20
EN-GJL250 grey cast
FKM
0 - 13 bar
NC — closed by spring power against the media (soft closing)
Magnetic switch 2-fold OPEN and CLOSE induct. 2-wire N/O contact

F2202/0402/7015-OF
DN20
EN-GJL250 grey cast
FKM
0 - 13 bar
NC — closed by spring power against the media (soft closing)
Free of oil and grease

F2202/0402/7015-VD
DN20
EN-GJL250 grey cast
FKM
0 - 13 bar
NC — closed by spring power against the media (soft closing)
vacuum + overpressure

F2202/0402/7015-XX
DN20
EN-GJL250 grey cast
FKM
0 - 13 bar
NC — closed by spring power against the media (soft closing)
No extra options

F2202/0402/7058-EB-VU
DN20
EN-GJL250 grey cast
FKM
0 - 13 bar
NC — closed by spring power against the media (soft closing)
Reed contact 2-wire RC12 Vacuum

F2202/0402/7058-EN
DN20
EN-GJL250 grey cast
FKM
0 - 13 bar
NC — closed by spring power against the media (soft closing)
Sensor inductive, 2-fold

F2202/0402/7058-EO
DN20
EN-GJL250 grey cast
FKM
0 - 13 bar
NC — closed by spring power against the media (soft closing)
Inductive sensor, double

F2202/0402/7058-OF
DN20
EN-GJL250 grey cast
FKM
0 - 13 bar
NC — closed by spring power against the media (soft closing)
Free of oil and grease

F2202/0402/7058-VD
DN20
EN-GJL250 grey cast
FKM
0 - 13 bar
NC — closed by spring power against the media (soft closing)
vacuum + overpressure

F2202/0402/7058-XX
DN20
EN-GJL250 grey cast
FKM
0 - 13 bar
NC — closed by spring power against the media (soft closing)
No extra options

F2202/0402/8005-EO-BIM-UNT-AG41X
DN20
EN-GJL250 grey cast
FKM
0 - 16 bar
NO — open by spring power
Magnetic switch 2-fold OPEN and CLOSE induct. 2-wire N/O contact

F2202/0402/8005-XX
DN20
EN-GJL250 grey cast
FKM
0 - 16 bar
NO — open by spring power
No extra options

F2202/0404/7005-EN
DN20
EN-GJL250 grey cast
PTFE
0 - 16 bar
NC — closed by spring power with the flow direction
Sensor inductive, 2-fold

F2202/0404/7005-EO
DN20
EN-GJL250 grey cast
PTFE
0 - 16 bar
NC — closed by spring power with the flow direction
Inductive sensor, double

F2202/0404/7005-OF
DN20
EN-GJL250 grey cast
PTFE
0 - 16 bar
NC — closed by spring power with the flow direction
Free of oil and grease

F2202/0404/7005-XX
DN20
EN-GJL250 grey cast
PTFE
0 - 16 bar
NC — closed by spring power with the flow direction
No extra options

F2202/0404/7015-EN
DN20
EN-GJL250 grey cast
PTFE
0 - 13 bar
NC — closed by spring power against the media (soft closing)
Sensor inductive, 2-fold

F2202/0404/7015-EO
DN20
EN-GJL250 grey cast
PTFE
0 - 13 bar
NC — closed by spring power against the media (soft closing)
Inductive sensor, double

F2202/0404/7015-EO-BIM-UNT-AG41X
DN20
EN-GJL250 grey cast
PTFE
0 - 13 bar
NC — closed by spring power against the media (soft closing)
Magnetic switch 2-fold OPEN and CLOSE induct. 2-wire N/O contact

F2202/0404/7015-OF
DN20
EN-GJL250 grey cast
PTFE
0 - 13 bar
NC — closed by spring power against the media (soft closing)
Free of oil and grease

F2202/0404/7015-XX
DN20
EN-GJL250 grey cast
PTFE
0 - 13 bar
NC — closed by spring power against the media (soft closing)
No extra options

F2202/0404/7058-EN
DN20
EN-GJL250 grey cast
PTFE
0 - 13 bar
NC — closed by spring power against the media (soft closing)
Sensor inductive, 2-fold

F2202/0404/7058-EO
DN20
EN-GJL250 grey cast
PTFE
0 - 13 bar
NC — closed by spring power against the media (soft closing)
Inductive sensor, double

F2202/0404/7058-OF
DN20
EN-GJL250 grey cast
PTFE
0 - 13 bar
NC — closed by spring power against the media (soft closing)
Free of oil and grease

F2202/0404/7058-XX
DN20
EN-GJL250 grey cast
PTFE
0 - 13 bar
NC — closed by spring power against the media (soft closing)
No extra options

F2202/0404/8005-EO-BIM-UNT-AG41X
DN20
EN-GJL250 grey cast
PTFE
0 - 16 bar
NO — open by spring power
Magnetic switch 2-fold OPEN and CLOSE induct. 2-wire N/O contact

F2202/0404/8005-XX
DN20
EN-GJL250 grey cast
PTFE
0 - 16 bar
NO — open by spring power
No extra options

F2202/0431/7005-VD
DN20
EN-GJL250 grey cast
NBR/NBR
0 - 16 bar
NC — closed by spring power with the flow direction
vacuum + overpressure

F2202/0431/7015-EO-BIM-UNT-AG41X
DN20
EN-GJL250 grey cast
NBR/NBR
0 - 13 bar
NC — closed by spring power against the media (soft closing)
Magnetic switch 2-fold OPEN and CLOSE induct. 2-wire N/O contact

F2202/0431/7015-VD
DN20
EN-GJL250 grey cast
NBR/NBR
0 - 13 bar
NC — closed by spring power against the media (soft closing)
vacuum + overpressure

F2202/0431/7058-VD
DN20
EN-GJL250 grey cast
NBR/NBR
0 - 13 bar
NC — closed by spring power against the media (soft closing)
vacuum + overpressure

F2202/0431/8005-EO-BIM-UNT-AG41X
DN20
EN-GJL250 grey cast
NBR/NBR
0 - 16 bar
NO — open by spring power
Magnetic switch 2-fold OPEN and CLOSE induct. 2-wire N/O contact

F2203/0304/7005-EN
DN25
EN-JS1025 ductile iron
PTFE
0 - 12 bar
NC — closed by spring power with the flow direction
Sensor inductive, 2-fold

F2203/0304/7005-EO
DN25
EN-JS1025 ductile iron
PTFE
0 - 12 bar
NC — closed by spring power with the flow direction
Inductive sensor, double

F2203/0304/7005-EO-BIM-UNT-AG41X
DN25
EN-JS1025 ductile iron
PTFE
0 - 12 bar
NC — closed by spring power with the flow direction
Magnetic switch 2-fold OPEN and CLOSE induct. 2-wire N/O contact

F2203/0304/7005-OF
DN25
EN-JS1025 ductile iron
PTFE
0 - 12 bar
NC — closed by spring power with the flow direction
Free of oil and grease

F2203/0304/7005-XX
DN25
EN-JS1025 ductile iron
PTFE
0 - 12 bar
NC — closed by spring power with the flow direction
No extra options

F2203/0304/7015-EN
DN25
EN-JS1025 ductile iron
PTFE
0 - 8 bar
NC — closed by spring power against the media (soft closing)
Sensor inductive, 2-fold

F2203/0304/7015-EO
DN25
EN-JS1025 ductile iron
PTFE
0 - 8 bar
NC — closed by spring power against the media (soft closing)
Inductive sensor, double

F2203/0304/7015-EO-BIM-UNT-AG41X
DN25
EN-JS1025 ductile iron
PTFE
0 - 8 bar
NC — closed by spring power against the media (soft closing)
Magnetic switch 2-fold OPEN and CLOSE induct. 2-wire N/O contact

F2203/0304/7015-OF
DN25
EN-JS1025 ductile iron
PTFE
0 - 8 bar
NC — closed by spring power against the media (soft closing)
Free of oil and grease

F2203/0304/7015-XX
DN25
EN-JS1025 ductile iron
PTFE
0 - 8 bar
NC — closed by spring power against the media (soft closing)
No extra options

F2203/0402/7005-EB-VU
DN25
EN-GJL250 grey cast
FKM
0 - 12 bar
NC — closed by spring power with the flow direction
Reed contact 2-wire RC12 Vacuum

F2203/0402/7005-EN
DN25
EN-GJL250 grey cast
FKM
0 - 12 bar
NC — closed by spring power with the flow direction
Sensor inductive, 2-fold

F2203/0402/7005-EO
DN25
EN-GJL250 grey cast
FKM
0 - 12 bar
NC — closed by spring power with the flow direction
Inductive sensor, double

F2203/0402/7005-EO-BIM-UNT-AG41X
DN25
EN-GJL250 grey cast
FKM
0 - 12 bar
NC — closed by spring power with the flow direction
Magnetic switch 2-fold OPEN and CLOSE induct. 2-wire N/O contact

F2203/0402/7005-OF
DN25
EN-GJL250 grey cast
FKM
0 - 12 bar
NC — closed by spring power with the flow direction
Free of oil and grease

F2203/0402/7005-VD
DN25
EN-GJL250 grey cast
FKM
0 - 12 bar
NC — closed by spring power with the flow direction
vacuum + overpressure

F2203/0402/7005-XX
DN25
EN-GJL250 grey cast
FKM
0 - 12 bar
NC — closed by spring power with the flow direction
No extra options

F2203/0402/7015-EB-VU
DN25
EN-GJL250 grey cast
FKM
0 - 8 bar
NC — closed by spring power against the media (soft closing)
Reed contact 2-wire RC12 Vacuum

F2203/0402/7015-EN
DN25
EN-GJL250 grey cast
FKM
0 - 8 bar
NC — closed by spring power against the media (soft closing)
Sensor inductive, 2-fold

F2203/0402/7015-EO
DN25
EN-GJL250 grey cast
FKM
0 - 8 bar
NC — closed by spring power against the media (soft closing)
Inductive sensor, double

F2203/0402/7015-EO-BIM-UNT-AG41X
DN25
EN-GJL250 grey cast
FKM
0 - 8 bar
NC — closed by spring power against the media (soft closing)
Magnetic switch 2-fold OPEN and CLOSE induct. 2-wire N/O contact

F2203/0402/7015-OF
DN25
EN-GJL250 grey cast
FKM
0 - 8 bar
NC — closed by spring power against the media (soft closing)
Free of oil and grease

F2203/0402/7015-VD
DN25
EN-GJL250 grey cast
FKM
0 - 8 bar
NC — closed by spring power against the media (soft closing)
vacuum + overpressure

F2203/0402/7015-XX
DN25
EN-GJL250 grey cast
FKM
0 - 8 bar
NC — closed by spring power against the media (soft closing)
No extra options

F2203/0402/7063-EN
DN25
EN-GJL250 grey cast
FKM
0 - 16 bar
NC — closed by spring power against the media (soft closing)
Sensor inductive, 2-fold

F2203/0402/7063-EO
DN25
EN-GJL250 grey cast
FKM
0 - 16 bar
NC — closed by spring power against the media (soft closing)
Inductive sensor, double

F2203/0404/7005-EN
DN25
EN-GJL250 grey cast
PTFE
0 - 12 bar
NC — closed by spring power with the flow direction
Sensor inductive, 2-fold

F2203/0404/7005-EO
DN25
EN-GJL250 grey cast
PTFE
0 - 12 bar
NC — closed by spring power with the flow direction
Inductive sensor, double

F2203/0404/7005-EO-BIM-UNT-AG41X
DN25
EN-GJL250 grey cast
PTFE
0 - 12 bar
NC — closed by spring power with the flow direction
Magnetic switch 2-fold OPEN and CLOSE induct. 2-wire N/O contact

F2203/0404/7005-OF
DN25
EN-GJL250 grey cast
PTFE
0 - 12 bar
NC — closed by spring power with the flow direction
Free of oil and grease

F2203/0404/7005-XX
DN25
EN-GJL250 grey cast
PTFE
0 - 12 bar
NC — closed by spring power with the flow direction
No extra options

F2203/0404/7015-EN
DN25
EN-GJL250 grey cast
PTFE
0 - 8 bar
NC — closed by spring power against the media (soft closing)
Sensor inductive, 2-fold

F2203/0404/7015-EO
DN25
EN-GJL250 grey cast
PTFE
0 - 8 bar
NC — closed by spring power against the media (soft closing)
Inductive sensor, double

F2203/0404/7015-EO-BIM-UNT-AG41X
DN25
EN-GJL250 grey cast
PTFE
0 - 8 bar
NC — closed by spring power against the media (soft closing)
Magnetic switch 2-fold OPEN and CLOSE induct. 2-wire N/O contact

F2203/0404/7015-OF
DN25
EN-GJL250 grey cast
PTFE
0 - 8 bar
NC — closed by spring power against the media (soft closing)
Free of oil and grease

F2203/0404/7015-XX
DN25
EN-GJL250 grey cast
PTFE
0 - 8 bar
NC — closed by spring power against the media (soft closing)
No extra options

F2203/0404/7063-EN
DN25
EN-GJL250 grey cast
PTFE
0 - 16 bar
NC — closed by spring power against the media (soft closing)
Sensor inductive, 2-fold

F2203/0404/7063-EO
DN25
EN-GJL250 grey cast
PTFE
0 - 16 bar
NC — closed by spring power against the media (soft closing)
Inductive sensor, double

F2203/0404/7063-OF
DN25
EN-GJL250 grey cast
PTFE
0 - 16 bar
NC — closed by spring power against the media (soft closing)
Free of oil and grease

F2203/0404/7063-XX
DN25
EN-GJL250 grey cast
PTFE
0 - 16 bar
NC — closed by spring power against the media (soft closing)
No extra options

F2203/0431/7005-EO-BIM-UNT-AG41X
DN25
EN-GJL250 grey cast
NBR/NBR
0 - 12 bar
NC — closed by spring power with the flow direction
Magnetic switch 2-fold OPEN and CLOSE induct. 2-wire N/O contact

F2203/0431/7005-VD
DN25
EN-GJL250 grey cast
NBR/NBR
0 - 12 bar
NC — closed by spring power with the flow direction
vacuum + overpressure

F2203/0431/7015-EO-BIM-UNT-AG41X
DN25
EN-GJL250 grey cast
NBR/NBR
0 - 8 bar
NC — closed by spring power against the media (soft closing)
Magnetic switch 2-fold OPEN and CLOSE induct. 2-wire N/O contact

F2203/0431/7015-VD
DN25
EN-GJL250 grey cast
NBR/NBR
0 - 8 bar
NC — closed by spring power against the media (soft closing)
vacuum + overpressure
Not the right product?
Use our filter and search function at the top of the page.